JD-3002 Carbon Dioxide Comprehensive Air Quality Temperature Humidity Detector(480g)
JD-3002 Carbon Dioxide Comprehensive Air Quality Temperature Humidity Detector(480g)
Spread the cost
Mobicred is a third-party credit option. Approval and terms are determined by Mobicred.
- Approval by Mobicred
- Rate & fees in your pre-agreement
- Repayments confirmed before acceptance
- R Your interest rate, fees and repayment schedule are shown in Mobicred's pre-agreement.
- ✓ Approval and your credit limit are determined by Mobicred.
- i Review the credit terms before accepting the agreement.
Available payment options are confirmed at checkout.
Continue to checkoutDon't have Mobicred yet? Visit Mobicred →
Credit is subject to Mobicred approval and terms. Your limit, interest rate, fees and repayment schedule are disclosed by Mobicred before acceptance. Mobicred terms and conditions
Duties & Import Tax Information
In Stock
Processing: 1–3 days
Duties & Import Tax Information
Tax Responsibilities
Any item may be subject to customs duties, import taxes and clearance fees unless the selected shipping method at checkout explicitly states that these charges are included. Where they are not included, the courier may contact you to collect the applicable charges before delivery.
Delivery & Processing
Delivery timeline
Processing: 1–3 days
Average transit: 5–15 business days
To see all available shipping methods and exact delivery times, add this product to your cart and use our shipping calculator.
Couldn't load pickup availability
Shipping Policy
Delivery timeline
Processing: 1–3 days
Average transit: 5–15 business days
Exact delivery times: use the shipping calculator in your cart
Check delivery options
To find all available shipping methods and exact delivery times, add the product to your cart and check using our shipping calculator.
Returns & Refunds
14-Day Returns
Request an eligible change-of-mind return within 14 days of delivery. The item must be unused, resalable and complete. You pay return shipping to the original dispatch warehouse, which may be outside South Africa, unless the item is defective, damaged, incorrect or incomplete.
Refunds & Your Rights
Approved refunds are processed to the original payment method within two business days. Your bank or payment provider may take longer. Your statutory rights under South African law are not affected.
Checkout & Privacy
Payment Processing
Payment is processed using the methods shown at checkout. See our Privacy Policy for how personal information is handled.
Privacy & Data Use
Our Privacy Policy explains how personal information is collected, used and shared.
Accepted payment methods
Visa Mastercard American Express
Ozow
Available options are confirmed at checkout.
Product Warranty
What is covered?
Manufacturing defects and internal faults are covered under our warranty terms.
What is not covered?
Please note that the warranty does not cover physical damage, water damage, or normal wear and tear caused by everyday usage.
Product details
Description
Instrument instructions:
1. After the test, the power of the equipment must be turned off to avoid accidents
2. Prevent the instrument from violent vibration
3. After placing the instrument for a long time, the odor gas will accumulate in the instrument, which will seriously affect the test results, in this case, the instrument must be placed in a cool and ventilated place, and then used for more than 1 hour (no operation is required during the ventilation process instrument)
4. The expired and defective products should be repaired in time.
5. Avoid shocking the sensor with gas higher than the measurement range, otherwise it may damage the sensor, and man-made damage is not covered by the warranty
Instrument introduction:
1. Digital temperature and humidity sensor
2. LCD display
3. Mute button: Turn on or off the alarm sound. In the silent mode, the " " symbol is not displayed and there is no alarm sound. The default is to turn on the sound
4. "+" button: When setting the alarm value, increase the value.
5. Power button: long press for 2 seconds to turn on or off the power, when power on, the number field counts down from 120
6. Temperature unit selection button: Celsius and Fahrenheit conversion
7. "-" button: When setting the alarm value, decrease the value
8. Setting button: Short press this button to set the alarm value of "CO2→TVOC→HCHO" in sequence, the original factory setting value will be displayed and flashing, and the parameter will be adjusted by the "+" button and "-" button, and the value will be displayed after 10 seconds. automatic storage
9. Power supply: DC5V built-in 1800mAh lithium battery
10. Dimensions: 195x95x35mm
11. Carton packaging weight: 270 grams
Display content introduction:
1. Alarm sound: press the "mute button" to operate
2. CO2 measurement range: 350ppm~2000ppm
3. TVOC measuring range: 0.000 mg/m3~2.000 mg/m3
4. HCHO measuring range: 0.000 mg/m3~1.000 mg/m3
5. Temperature display: press the "temperature unit selection button" to operate
6. Measuring range: 0-90.0 degrees Celsius, 32-194 degrees Fahrenheit
7. Environmental quality reminder: excellent, the detection value is lower than the set value; good, the CO2 detection value is 50ppm higher than the set value
8. The TVOC detection value is 0.01 mg/m3 higher than the set value
9. The detected value of HCHO is 0.03 mg/m3 higher than the set value
10. Pollution: Buzzer fast sound alarm
11. The detected value of CO2 is 100ppm higher than the set value
12. The TVOC detection value is 0.02 mg/m3 higher than the set value
13. The detected value of HCHO is 0.06 mg/m3 higher than the set value
14. When the battery power is too low, the battery box will flash to remind the user to charge
15. When charging, the characters in the battery frame will flash in sequence until the battery symbol is fully displayed when the battery is fully charged
16. Humidity measurement range: 0~99.0RH
important hint:
1. Before use, please read the following detailed introduction carefully, and use the instrument correctly according to the manual
2. Do not disassemble the instrument or throw it into fire
3. Avoid operating the instrument in a strong wind environment
4. Avoid shock and drop
5. If it is not used for a long time, the warm-up time for the power-on will be longer
6. Note: Do not let liquid flow into the instrument
Questions about features, compatibility, or warranty? Chat with our local support team!